Rollout switch open raypak - The Raypak 005899F Thermal Cut-Off Fuse (650914) is in stock and ready to ship. This thermal fuse can be counted on for dependability and accuracy – plus installation is simple. ... Hot Tub Pressure Switches. THERMOSTATS & SENSORS. SPA ELECTRICAL. PLUGS & RECEPTACLES. HOT TUB ACCESSORIES. CHEMICALS. CHEMICALS. POOL …

 
Re: RayPak Model#: P-R406A-EP-C (propane pool heater) The Water Flow switch keeps on failing out shutting down the heater and then auto-resetting and restarting. Even after replacing the switch with a … read more. Seaside heights nj weather 10 day forecast

Raypak 266A Pdf User Manuals. View online or download Raypak 266A Installation & Operating Instructions Manual, Installation And Operation Manual, Replacement Instructions Manual Bachelor's of Science. 637 satisfied customers. This is to my question on how to wire a Jandy Aqualink RS8. OK, So this is a follow up to my question on how to wire a Jandy Aqualink RS8 to a new Raypak pool heater. I was told to connect the pins 1 and 2 on … read more.The most common cause of this type of issue is one of your sensors goin bad, typically it is related to the pressure switch or the over limit sensor. There is also the possibility that it is the flame sensor as well. One thing you can try is power cycling the unit. ... Raypak heater: has reading Water Sw open. Will not spark or ignite.Bachelor's of Science. 637 satisfied customers. This is to my question on how to wire a Jandy Aqualink RS8. OK, So this is a follow up to my question on how to wire a Jandy Aqualink RS8 to a new Raypak pool heater. I was told to connect the pins 1 and 2 on … read more.The roll out switch tripped and I had to figure out why.In... On this Saturday call I respond to a no heat where I had to perform a roll out switch diagnosis. The roll out switch tripped and I had ...If the rollout switch was open, the condition(s) that caused the rollout switch to open must be corrected before the rollout switch is replaced. The rollout switch opens if there is an overtemperature condition at the entrance to the firebox. ... Both my neighbours & my Raypak heater were installed in new pools in July 2017 & both …Flame rollout switches trip when the heat exchanger is damaged, or the vent is clogged. If there is a fluctuation in gas pressure within the furnace, it can also cause the flame rollout switch to trip and can be temporarily reset. Resetting the flame rollout switch is only a temporary fix.May 15, 2020 · Take the panel off and check the crimp terminals. If they look good, it might be a bad switch, or for some reason, water is not reaching the header...check any valves near the intake and make sure they are on and your pump is not on low speed. If you have a heater bypass valve, turn that off to ensure full flow to the heater. If you're thinking of buying yourself or a loved one a Nintendo Switch this holiday season, do it. A little over eight months ago, Nintendo released the Switch, a video game system that was unlike anything that had come before it. It was a ...Replacing a single pole switch with a dimmer switch is not that difficult to do. Watch this video to find out how to go about it. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All Radio Show Latest View All ...I have a Raypak 406 heater. Just had the pool opened yesterday and started the heater today. 2 minutes later, the rollout switch opened. I was able to get another one and replaced it, but same thing h … read moreThe Raypak pool heater rollout switch (SW open) allows for the gas valve on a Raypak pool heater to be opened and closed with ease. The switch is located on the "rollout" side of the unit, usually near the top or bottom. To open it, simply turn it to the left until you hear a click sound; this will release any pressure that has built up in ...I have a 3 year old Raypak pool heater. It does not turn on and gives me the following message: Rollout SW open. ... The massage reads RollOut Sw Open, which I guess means Rollout switch open. ... The flame roll out switch keeps tripping. When reset, the furnace fires up, delivers heat normally, and then when the thermosat is …- Check for open contacts on switches in safety circuit . Reset flame roll out switches and manual reset limit switches . - Check wiring . Wire off limit or flame rollout switch shorting to unit . - Defective limit or flame rollout switch . Verify and replace if required . - Defective board, not letting 24 VAC through limits .May 20, 2014 · Sep 5, 2008. 2,196. Silicon Valley, CA. May 19, 2014. #2. Check and make sure that all the burners are firing properly and blue. Roll out occurs when either the exchanger is sooted up, or you have one or more clogged burners. Roll out sensor is one time use, no reset and must be replaced (if it is open). Report. 8-M Control Bezel Digital (Includes Switch Decal) N/A 014886F 9-M Switch/Decal-Membrane N/A 014887F 10-M Control Bezel Cover N/A 014888F 11-M Line Cord 011609F 011609F 12-M Roll-Out Safety Switch 005899F 005899F 13-M Touch-up Paint Cool Dark Gray 750256 750256 Warm Dark Gray 750258 750258 14-M Gas Line Finish Flange 016160F 016160F P PILOT Keep your swimmers comfortable with Raypak 106A and 156A pool and spa heater parts from Parts4Heating. Our inventory of replacement P-R105A and P-R-146A Raypak parts includes pilots, transformers, fuse kits and more. ... Raypak 009133F Pressure Switch 11 PSI Special-See Water Pressure Switch Adj. $93.73. $62.73. Raypak 009493F Rocker …Raypak 005899F 130° 55A/105A/155A Thermal Cut-Off Fuse Kit. 4.4 out of 5 stars 71. ... Compatible with Raypak 005899F Thermal Cut-Off Fuse Rollout Switch Replacement Kit for Swimming Pool Heaters Parts Plug Fuses Thermal Fuse Link Accessories, White ... Rheem Furnace Replacement Limit Switch L350. 4.5 out of 5 stars 624. Save 14%. …Why does Raypak pool heater display error: Water Sw Open? Don't knmow\\ - Answered by a verified Pool and Spa ExpertTwo way electrical switches have two types of wires connected to them: common wires and traveler wires. The common wire is the only wire that needs to be attached to a particular screw, often the dark one, on the 2-way switch.15. Santa Clarita. Apr 14, 2023. #1. Hey there all I began experiencing a strange issue with my Raypak RP2100 336K heater. This is an old heater with the analog display so I can't see a code to narrow the issue down. Three months ago I replaced the PC board, thermometer sensor, high limit switches, thermal fuse, and the water pressure …Raypak, 156A, 150,000 BTU, 3 yrs old. Contractor's Assistant: ... It should be noted a roll out switch being open doesnt always mean the burners are stopped up. Pool heater says ROLLOUT sw open. heater not working. Raypak 156, 2 years old. I started it up 2 weeks ago and it - Answered by a verified Pool and Spa Expert. ... Hi I was switching out the rollout switch on my Raypak pool heater and it sparked. and now there's no power. I check the circuit board in the basement and everything was still on.Raypak 206A, 266A, 336A, 406A Digital Atmospheric Gas Heater Parts ... Rocker Switch R185B-R405B. $32.90. 53 ... Customer Service is open Monday-Friday, 9AM-6PM CT ...Sep 5, 2008. 2,196. Silicon Valley, CA. May 19, 2014. #2. Check and make sure that all the burners are firing properly and blue. Roll out occurs when either the exchanger is sooted up, or you have one or more clogged burners. Roll out sensor is one time use, no reset and must be replaced (if it is open). Report."If it is a Raypak heater, the roll out sensor is a one time use part, like a fuse, it isnt re-settable." This is a HUGE issue with these Raypak pool heaters. I have now wind issues. I have a heater stack. The furnace is 2 years old & yet, the rollout switch keeps breaking with nop means to reset it after cleaning.Raypak 005899F 130° 55A/105A/155A Thermal Cut-Off Fuse Kit. 4.5 out of 5 stars 72. $11.99 $ 11. 99. FREE ... Compatible with Raypak 005899F Thermal Cut Off Fuse Rollout Switch Replacement Kit for Swimming Pool Heaters Parts Plug Fuses Thermal Fuse Link Accessories, White (1) 4.1 out of 5 stars 11. $10.99 $ 10. 99. FREE delivery Wed, Oct 4 …Apr 17, 2020 · Ask your Questions or search from our database of answers: https://askthepoolguy.com/questions/ask/ Make sure you Subscribe so you get your answer! https://w... The Raypak 006035F Roll Out Switch is also referred to as a Roll Out Fuse or a Temp Sensor.It is used on RayPak Digital Low Nox Heaters and RP2100 digital heaters. It works with the 005899F Thermal Fuse and is designed to fail if excessive heat or flames are sensed in the front of the cabinet.Raypak 005899F Thermal Cut-Off Fuse 106/156-Kit (3) : ... 5.0 out of 5 stars Raypac flame rollout switch. Reviewed in the United States 🇺🇸 on July 5, 2023. Number of Items: ... Replaced the roll out switch on my Raypak pool heater. Priced right too. Read more. Report. mc20piece.Pool heater says ROLLOUT sw open. heater not working. Raypak 156, 2 years old. I started it up 2 weeks ago and it - Answered by a verified Pool and Spa Expert #1 Moved from Here . Moderator - Marty Jayryght said: Was wondering if someone could please help me out on this; I have a Raypak Natural Gas Heater (auto start) bought and installed in 2013 and just turned it on to heat the pool and it's reading "Rollout SW Open".View and Download Raypak CR-206A specification sheet online. ASME Digital/Millivolt Atmospheric Gas Pool Heaters. CR-206A swimming pool heater pdf manual download. Also for: Cr406a. ... Flame Rollout …For technical questions and support, visit us at: http://raypak.com/contactMay 19, 2013 · 37,770 Silver Spring, MD May 18, 2013 #2 Here is what I found in the manual: Roll Out Sw Open - Rollout Switch - verify gas pressure, combustion air, blocked heat exchanger, proper vent size/connections, high wind conditions. Report ps0303 0 TFP Expert Swimming Pool Heater Raypak D-2 POWER VENT 206A Installation & Operating Instructions Manual. For 206a, 207a, 266a; 267a; 336a; 406a 407a swimming pool & spa heaters (20 pages) Swimming Pool Heater Raypak 399 Illustrated Parts List. Commercial model type: h, w, wh, & p (6 pages) Gas Heater Raypak 266L Installation And Operation …#1 Moved from Here . Moderator - Marty Jayryght said: Was wondering if someone could please help me out on this; I have a Raypak Natural Gas Heater (auto start) bought and installed in 2013 and just turned it on to heat the pool and it's reading "Rollout SW Open".Another cause would be a tripped rollout switch. If that is the case and the heater is an older model, that strongly indicates that the heat exchanger is worn, rusted, or cracked. Over time, the chamber that houses the flame will undoubtedly rust and break.In this event, you might as well shut off the furnace rather than waiting for the flame rollout switch to trip. step 6: Only Reset the Flame Rollout Switch One or Two Times. If you observe flame rollout with the panel off, or if the flame rollout switch trips again, the safest practice is to kill the power and gas to the furnace.Just an update regarding this three years later. Got the heat exchanger cleaned about a year after this happened and still rolling out. The tech said it wasn't all that dirty.- Check for open contacts on switches in safety circuit . Reset flame roll out switches and manual reset limit switches . - Check wiring . Wire off limit or flame rollout switch shorting to unit . - Defective limit or flame rollout switch . Verify and replace if required . - Defective board, not letting 24 VAC through limits .Apr 25, 2020 · I changed a roll out switch on my raypak pool heater. When I turned it back on, I heard it click, and the read out on the screen went out. If it worked fine prior to the rollout switch going bad. … read more How do I reset the rollout switch open in a Raypak pool heater 156k that is digital? It is a brand new heater that has worked fine for 10 days. It will not kick on …Amazon.com: Raypak Rollout Switch 1-48 of 70 results for "raypak rollout switch" Results Price and other details may vary based on product size and color. Best Seller …Raypak 266A Pdf User Manuals. View online or download Raypak 266A Installation & Operating Instructions Manual, Installation And Operation Manual, Replacement Instructions Manual As far as water/plumbing, I have a bypass line installed as well as the in/out to the heat pump, and the plumbing was done according to Raypak's instruction manual. Water pressure at the filter is around 20psi with bypass valve …Thermal Cut Off Fuse 152C°, Compatible with Raypak 005899F Thermal Cut Off Fuse Rollout Switch Replacement Kit for Swimming Pool Heaters Parts Plug Fuses Thermal Fuse Link Accessories, White (1) 11. $1099. FREE delivery Wed, Oct 11 on $35 of items shipped by Amazon. Or fastest delivery Mon, Oct 9.4) Turn gas knob to "ON". If ignition module locks out. reset by interrupting power to boiler. 5)Vent switch is open. 5) Check for blockage of venting system or disconnected vent piping. After problem is corrected push button to reset, or replace single-use type vent switch. 6)Roll-out switch is open.8-M Control Bezel Digital (Includes Switch Decal) N/A 014886F 9-M Switch/Decal-Membrane N/A 014887F 10-M Control Bezel Cover N/A 014888F 11-M Line Cord 011609F 011609F 12-M Roll-Out Safety Switch 005899F 005899F 13-M Touch-up Paint Cool Dark Gray 750256 750256 Warm Dark Gray 750258 750258 14-M Gas Line Finish Flange 016160F 016160F P PILOT A limit circuit lockout can happen if switches in the limit circuit are open longer than three minutes. Like an ignition lockout, a limit circuit lockout may auto-reset after a few hours, though some parts, like a flame rollout switch, may need to be reset manually. High surface temperatures and flame rollout can cause this type of lockout to ...Yellow flame above the burners is indicative of inadequate combustion air (various causes). Blue flame below the burners may indicate more combustion air is available from the outside after the flame starts to roll out. There should be a pipe union to the left of the gas valve.Are you looking for a reliable and affordable mobile phone service provider? If so, you should consider switching to Ting Mobile. Ting Mobile is a low-cost mobile phone service provider that offers great value for money.Bachelor's of Science. 637 satisfied customers. This is to my question on how to wire a Jandy Aqualink RS8. OK, So this is a follow up to my question on how to wire a Jandy Aqualink RS8 to a new Raypak pool heater. I was told to connect the pins 1 and 2 on … read more.The Raypak Pool Heater RollOut Sw OPEN error is related to the water flow to your pool heater. That means that this message is an indication that there is a restriction of water flow into the heater.Nov 23, 2015 · Step 1, replaced the ROL switch. It's very simple. Shut off all power (I also closed the gas line). The switch is located on the bottom left corner behind the front panel, connected by two red wires. Simply remove the screw holding them in place, unplug the wires, and plug them into the new switch, then place it back where it belongs. Raypak 005899F Thermal Cut-Off Fuse 106/156-Kit (3) : ... 5.0 out of 5 stars Raypac flame rollout switch. Reviewed in the United States 🇺🇸 on July 5, 2023. Number of Items: ... Replaced the roll out switch on my Raypak pool heater. Priced right too. Read more. Report. mc20piece.A relay switch, or simply a relay, is a small electromechanical device that controls a pair of movable contacts or circuit parts, moving from an open to a closed position and vice versa.If your power goes out, one of the safest and easiest ways to switch power to a portable generator to your electrical panel. You can either install a manual or automatic transfer switch. The following guidelines are for how to install a tra...Raypak 005899F Thermal Cut-Off Fuse 106/156-Kit (2) : ... Replaced the roll out switch on my Raypak pool heater. Priced right too. Read more. Report. mc20piece. 5.0 out of 5 stars Worked. ... Open-Box Discounts : Whole Foods Market We Believe in Real Food: Amazon Renewed Like-new productsMay 10, 2023 · Another cause would be a tripped rollout switch. If that is the case and the heater is an older model, that strongly indicates that the heat exchanger is worn, rusted, or cracked. Over time, the chamber that houses the flame will undoubtedly rust and break. Aug 13, 2018 · "If it is a Raypak heater, the roll out sensor is a one time use part, like a fuse, it isnt re-settable." This is a HUGE issue with these Raypak pool heaters. I have now wind issues. I have a heater stack. The furnace is 2 years old & yet, the rollout switch keeps breaking with nop means to reset it after cleaning. Raypak 005899F Thermal Cut-Off Fuse 106/156-Kit (5) : Amazon.ca: ... Replaced the roll out switch on my Raypak pool heater. Priced right too. Read more. Report. mc20piece. ... Open-Box Discounts: Whole Foods Market We Believe in Real Food: Amazon Renewed Like-new products you can trust:Jun 21, 2015 · How do I reset the rollout switch open in a Raypak pool heater 156k that is digital? It is a brand new heater that has worked fine for 10 days. It will not kick on because it reads rollout switch open … read more Raypak 206A, 266A, 336A, 406A Digital Atmospheric Gas Heater Parts ... Rocker Switch R185B-R405B. $32.90. 53 ... Customer Service is open Monday-Friday, 9AM-6PM CT ...A limit circuit lockout can happen if switches in the limit circuit are open longer than three minutes. Like an ignition lockout, a limit circuit lockout may auto-reset after a few hours, though some parts, like a flame rollout switch, may need to be reset manually. High surface temperatures and flame rollout can cause this type of lockout to ...Remove right and left side access panels (Figure 1). 2. Disconnect wires at high limit, AGS (automatic gas shut-off), and pressure switch on the in/out header (Figure 2). 3. AFT Models: Remove the thermostat temperature sensor by …And “rollout SW open” is visible on display when the roll out sensor is failing. We will now take a detailed look at solving each of these sensor failures. We will explore the possible causes of these different sensor failures and how to solve them. Note: Also read and know how to fix Raypak pool heater ignition failure. 1. Temperature ...For professionals. Find quality products and parts in the new Master Catalog which is a complete reference to Raypak authorized replacement parts. Find images and descriptions of products that are stocked and ready to ship. There is no need to go anywhere else for your professional HVAC, Water Heater parts, supplies, accessories and services. 0:00 / 4:05 How To Reset Rollout Switch Open In Raypak Pool Heater? JustAnswer-Q&A 7.52K subscribers Subscribe 3.5K views 2 years ago From …Swimming Pool Heater Raypak D-2 POWER VENT 206A Installation & Operating Instructions Manual. For 206a, 207a, 266a; 267a; 336a; 406a 407a swimming pool & spa heaters (20 pages) Swimming Pool Heater Raypak 185A Replacement Instructions Manual. P.c. board, temperature control & sensor (kit #010253f) for all digital gas pool heaters (18 …Raypak Model 156A Heater Replacement Parts. $7.49 Standard Shipping on all orders. ... 1-M Pressure Switch Item Number: 006737F. Details: Raypak Item Number 006737F Keep your swimmers comfortable with Raypak 106A and 156A pool and spa heater parts from Parts4Heating. Our inventory of replacement P-R105A and P-R-146A Raypak parts includes pilots, transformers, fuse kits and more. ... Raypak 009133F Pressure Switch 11 PSI Special-See Water Pressure Switch Adj. $93.73. $62.73. Raypak 009493F Rocker …From https://www.justanswer.com/ythiJustAnswer Customer: I have a Raypak pool heater (Model C-R266A-EN-X 010199).JustAnswer Customer: The heater will only op...For over 50 years, Raypak has been the world's leading manufacturer of copper finned boilers and heaters. From a modest beginning in 1947 in founder Al Whittel's garage in Southern California, Raypak now supplies equipment worldwide. Among Raypak's most trusted pool products include Raypak pool heaters for pools and spas.Switching phone carriers can be a daunting task, but it can also save you a lot of money on your monthly bill. If you’re looking to switch carriers, there are a few things you should keep in mind to ensure that you find the best deals.As technology advances, it’s important to keep up with the latest operating systems. Windows 7 is no longer supported by Microsoft, so if you’re still using it, it’s time to make the switch to Windows 10. Making the transition doesn’t have ...One common issue pool owners face is the rollout switch opening, which can cause your pool heater to shut down. To ensure this problem doesn’t occur, you must follow these five guidelines. Firstly, avoid using specific phrases while writing and make it sound like a human wrote it. Secondly, limit your sentences to 20 words max.Rheem recently unveiled their new and improved pool heater rollout switch, the Sw Open. The innovative design allows for easier installation and maintenance of the heater, as well as a more secure connection …Liquid Chlorine. May 21, 2019. #1. We have a Raypak 266A natural gas heater and it’s been running on and off since opening to keep our pool at a comfortable temp for the kids to swim. It’s a really windy day here in Minnesota today and I went out to turn the heater off for the night and noticed a code “ROLLOUT SW OPEN” on the LCD screen.If you’re considering an upgrade to your home’s hot water system, you may be wondering whether switching to a tankless water heater is worth it. While there are some definite advantages to going tankless, there are also a few drawbacks that...One common issue pool owners face is the rollout switch opening, which can cause your pool heater to shut down. To ensure this problem doesn’t occur, you must follow these five guidelines. Firstly, avoid using specific phrases while writing and make it sound like a human wrote it. Secondly, limit your sentences to 20 words max.

5. The Condensate Drain is Blocked. Finally, if your pressure switch is misbehaving, it may also be a sign that your furnace’s condensate drain is blocked. Of course, this only applies to condensing furnaces. However, it’s a pervasive problem because nearly 90% of all furnaces today are condensing units.. North carolina to virginia

rollout switch open raypak

The Raypak 005899F Thermal Cut-Off Fuse (650914) is in stock and ready to ship. This thermal fuse can be counted on for dependability and accuracy – plus installation is simple. ... Hot Tub Pressure Switches. THERMOSTATS & SENSORS. SPA ELECTRICAL. PLUGS & RECEPTACLES. HOT TUB ACCESSORIES. CHEMICALS. CHEMICALS. POOL …Jul 14, 2022. #14. RaypakM266A said: I am not sure if the 2nd picture uploaded the first time, showing up close the fried frog that damaged the board. But here is another update - the heater ran fine for about 5 hours. And then the circuit breaker got tripped. The main motor is now tripping the circuit breaker, looks like the motor crapped out.The Raypak 006035F Roll Out Switch is also referred to as a Roll Out Fuse or a Temp Sensor. It is used on RayPak Digital Low Nox Heaters and RP2100 digital heaters. It …Oct 10, 2018 · My Favorite Tool: https://amzn.to/3NIFJuOReplacement Roll-out Switches: https://amzn.to/3VlYXLATools We Recommend: https://amzn.to/3CssuwhOne common symptom ... Swimming Pool Heater Raypak D-2 POWER VENT 206A Installation & Operating Instructions Manual. For 206a, 207a, 266a; 267a; 336a; 406a 407a swimming pool & spa heaters (20 pages) Swimming Pool Heater Raypak 185A Replacement Instructions Manual. P.c. board, temperature control & sensor (kit #010253f) for all digital gas pool heaters (18 pages) You just pull it out of the connector and put a new one in. The leads just fit into the connector. The sensor looks like a diode or resistor. 1. hostmostoast • 3 yr. ago. It's so easy to replace that you really shouldn't need a manual. Look at the parts breakdown of where it is and get a nut-driver out. A relay switch may be used to regulate the flow of current between a circuit and device. Relay switches make it the transfer of current safe, particularly if the circuit and the output device are unable to handle a direct electrical connect...The Raypak Pool Heater RollOut Sw OPEN error is related to the water flow to your pool heater. That means that this message is an indication that there is a restriction of water flow into the heater.Price: $2,070.24. I acknowledge this is a special order item. Yes, I acknowledge. Currently Unavailable. 1-HP Heat Exchange Assembly Cupro Nickel Item Number: 010359F. Details: Raypak Item Number 010359F. Used On Raypak R406A Digital Heaters - prior to 7/2013. Used On Raypak Model R407A Digital Low NOx Heaters.Find the perfect heating solution with ease. Please provide the required information in the sales form below and your representative will be in touch with you soon.Raypak Heater Reading "Rollout SW Open"ul. Thread starter Jayryght; Start date Aug 19, 2016; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair ... I have read elsewhere on this site someone having a similar problem and have established that the rollout switch is open and I have found it. It does not have a button …Switching financial advisors can be hard. Whether you want lower fees or better care, here's how to ditch your current financial advisor and find a new one. Calculators Helpful Guides Compare Rates Lender Reviews Calculators Helpful Guides ...Brand: Raypak. 4.0 12 ratings. $2,09600. FOR USE UP TO 2000 FT ELEVATION ONLY RayPak 150,000 BTU Natural Gas Above Ground Pool Heater (156A) The Raypak 156A is the perfect choice for larger above-ground pools, spas and inground pools. The 156 has up to 50 more BTUs than the competitors above-ground pool …Jul 2, 2019 · 399k BTU RayPak gas pool Heater service call Take the panel off and check the crimp terminals. If they look good, it might be a bad switch, or for some reason, water is not reaching the header...check any valves near the intake and make sure they are on and your pump is not on low speed. If you have a heater bypass valve, turn that off to ensure full flow to the heater.In this event, you might as well shut off the furnace rather than waiting for the flame rollout switch to trip. step 6: Only Reset the Flame Rollout Switch One or Two Times. If you observe flame rollout with the panel off, or if the flame rollout switch trips again, the safest practice is to kill the power and gas to the furnace.The Raypak Standard Digital is good to 2,000 feet. The Raypak Digital low NOx is good to 5,000 feet. Atmospheric heaters: Rated inputs are suitable for up to 2,000 feet elevation. For elevations above 2000 feet, reduce gas input 4% for each 1,000 feet above sea level, as high elevation reduces combustion performance..

Popular Topics